Compressor unit
maximal pressure up to 2850 psi (200 bars), outlet flow is 0,078 cubic meter per hour
(Model UK-2)
Model UK-2
1. UK-2 is used for following operations:
- For filling air of valves and pressurized vessels;
- For creation of air pressure and compression of air up to 2850 psi (200 bars);
- For pneumatic tests of pipeline valves and pressurized vessels;
- For pneumatic tests and adjustment of safety (relief) valve.
2. Technical specifications:
| Inlet gas: |
air |
| Outlet flow of air from compressor: |
0,078 cubic meter per hour at pressure 200 bar |
| Maximal outlet pressure: |
2850 psi (200 bars) |
| Outlet flow of cooling water: |
0,6 cubic meter per hour |
| Pressure of cooling water, no more: |
1 bars |
| Power of motor: |
7,5 kilowatt |
| Outlet air temperature : |
+1º� up to + 40 º� |
| Overall dimensions : length |
1563 mm |
| width |
1350 mm |
| height |
2066 mm |
| Weight : |
940 kg |
3. UK-2 included:
- Air compressor;
- Tanks (storage system) volume is 150 liters (3 tank by 50 liters everyone) for pressure up to 2850 psi (200 bars);
- Control panel used for control of testing process (included monometers, gauges, warning indication, condensate collector, tubes, fittings );
- Bed plate;
- Tubes.
4. Control of testing:
- on manometer, on device of indicator for measurement of leakages and visual.
5. Control panel has all necessary gauges for measurement and control of testing .
6. All metal details contacting with water are protected from corrosion.
7. Ambient temperature: +1 up to +40 � �.
8. You must need for test bench of following:
- Inlet water with pressure 1,5 bar (21 psi);
- Electric power supply 380V, 50 Hz. |